Back to Search Start Over

Novel simple templates for reproducible positioning of skin applicators in brachytherapy

Authors :
Silvia Rodríguez Villalba
Maria Jose Perez-Calatayud
Juan Antonio Bautista
Vicente Carmona
Francisco Celada
Alejandro Tormo
Teresa García-Martinez
José Richart
Manuel Santos Ortega
Magda Silla
Facundo Ballester
Jose Perez-Calatayud
Source :
Journal of Contemporary Brachytherapy, Vol 8, Iss 4, Pp 344-348 (2016)
Publication Year :
2016
Publisher :
Termedia Publishing House, 2016.

Abstract

Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the positioning of the applicator. These templates are freely available upon request. Material and methods: Templates that were developed by University and Polytechnic Hospital La Fe (La Fe) and Hospital Clínica Benidorm (ITIC) in cooperation with Elekta, consist of a thin sheet made of transparent acrylic. For each applicator, a crosshair and two different circles are drawn on these templates: the inner one corresponds to the useful beam, while the outer one represents the external perimeter of the applicator. The outer circle contains slits that facilitate to draw a circle on the skin of the patient for exact positioning of the applicator. In addition, there are two perpendicular rulers to define the adequate margin. For each applicator size, a specific template was developed. Results: The templates have been used successfully in our institutions for more than 50 patients’ brachytherapy treatments. They are currently being used for Esteya and Valencia applicators. Conclusions : The template La Fe-ITIC is simple and practical. It improves both the set-up time and reproducibility. It helps to establish the adequate margins, an essential point in the clinical outcome.

Details

Language :
English
ISSN :
1689832X and 20812841
Volume :
8
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Journal of Contemporary Brachytherapy
Publication Type :
Academic Journal
Accession number :
edsdoj.30bc5d6aa36c43ae98bcf3a610009c4f
Document Type :
article
Full Text :
https://doi.org/10.5114/jcb.2016.61713