Comparison of a 2.7-mm and 3.5-mm locking compression plate for ulnar fractures: a biomechanical evaluation

Authors :
Jenna M. Wahbeh, MS
Benjamin V. Kelley, MD
Cyrus Shokoohi, BS
Sang-Hyun Park, PhD
Sai K. Devana, MD
Edward Ebramzadeh, PhD
Sophia N. Sangiorgio, PhD
Devon M. Jeffcoat, MD
Source :
OTA International, Vol 6, Iss 3 (2023)
Publication Year :
2023
Publisher :
Wolters Kluwer, 2023.

Abstract

Abstract. Objectives:. Implant prominence after ulnar fracture fixation may be mitigated by the use of lower profile plates. The biomechanical strength and stability of 2.7-mm and 3.5-mm locking compression plates for fixation were compared. Methods:. Two fracture conditions, transverse (N = 10) and oblique (N = 10), were evaluated in an in vitro study. Half of the specimens for each condition were fixed with 2.7-mm plates and the other half with 3.5-mm plates, all fixed with conventional dynamic compression mechanisms. Specimens were loaded under ±2 Nm of cyclic axial torsion, then under 10 Nm of cyclic cantilever bending, and bending to failure. Interfragmentary motion and strain were analyzed to determine construct stability as a function of fracture pattern and plate size. Results:. Interfragmentary motion was significantly larger in all constructs fixed with 2.7-mm plates, compared with 3.5-mm plates (P < 0.01). The 2.7-mm constructs with transverse fractures had the greatest motion, ranging between 5° and 10° under axial rotation and 5.0–6.0 mm under bending. Motions were the lowest for 3.5-mm constructs with oblique fractures, ranging between 3.2 and 4.2 mm under bending and 2°–3.5° for axial rotation. For oblique fractures, the bending moment at ultimate failure was 31.4 ± 3.6 Nm for the 2.7-mm constructs and 10.0 ± 1.9 Nm for 3.5-mm constructs (P < 0.01). Similarly, for transverse fractures, the bending moment was 17.9 ± 4.0 Nm for the 2.7-mm constructs and 9.7 ± 1.3 Nm for the 3.5-mm constructs (P < 0.01). Conclusions:. Although 3.5-mm plates were more effective at reducing fracture motion, they were consistently associated with refracture at the distal-most screw hole under load to failure. By contrast, 2.7-mm plates plastically deformed despite excessive loads, potentially avoiding a subsequent fracture. Level of Evidence:. Level V.

Subjects

Subjects :
Orthopedic surgery
RD701-811

Details

Language :
English
ISSN :
25742167 and 00000000
Volume :
6
Issue :
3
Database :
Directory of Open Access Journals
Journal :
OTA International
Publication Type :
Academic Journal
Accession number :
edsdoj.30ae9c56b2a242878d0f8719a45062cb
Document Type :
article
Full Text :
https://doi.org/10.1097/OI9.0000000000000278