Posición efectiva del lente intraocular en la facoemulsificación diagnosticado por biomicroscopia ultrasónica Effective position of the intraocular lens diagnosed with ultrasonic biomicroscopy in phacoemulsification

Authors :
Juan Raúl Hernández Silva
Leyda Elena Galá Herrera
Alexander Pérez Llanes
Meisy Ramos López
Reinaldo Rios Caso
Marcelino Rio Torres
Source :
Revista Cubana de Oftalmología, Vol 23, Iss 2, Pp 260-276 (2010)
Publication Year :
2010
Publisher :
Editorial Ciencias Médicas, 2010.

Abstract

OBJETIVO: Determinar la posición efectiva del lente intraocular en la facoemulsificación diagnosticado por biomicroscopia ultrasónica y su relación con la "sorpresa refractiva" posquirúrgica. MÉTODOS: Se realizó un estudio descriptivo y prospectivo de una muestra de 176 ojos de 100 pacientes operados de catarata por facoemulsificación con la técnica de Pre chop, en el Servicio de Microcirugía Ocular del Instituto Cubano de Oftalmología "Ramón Pando Ferrer", a los que se le determinó la posición efectiva del lente intraocular en la facoemulsificación diagnosticado por biomicroscopia ultrasónica y su relación con la "sorpresa" refractiva posquirúrgica. RESULTADOS: La mayoría de los pacientes estudiados, fueron del sexo masculino de la tercera edad, se diagnóstico la posición efectiva del lente intraocular en saco-surco por biomicroscopia ultrasónica, con lo que se logró la mejor agudeza visual corregida posoperatoria en todos los grupos de estudio, la distancia de la cara posterior del iris al lente intraocular, diagnosticada por biomicroscopia ultrasónica, en pacientes con lente intraocular en saco capsular demostró un valor constante, la mayoría de pacientes normo corregidos tenían el lente intraocular en saco capsular, los lente intraocular ubicados en la posición saco-surco, cuya háptica se encontraba con mayor angulación, tenían un cilindro posoperatorio promedio mayor, no se encontraron diferencias significativas entre el cilindro posoperatorio promedio obtenido. CONCLUSIONES: Queda demostrada la importancia de la biomicroscopia ultrasónica en la determinación de la posición del lente intraocular en los pacientes operados. Es determinante la localización del lente intraocular en el defecto refractivo posoperatorio, se destaca en la posición saco surco la existencia de un cilindro posoperatorio mayor.OBJECTIVE: To determine the effective position of the intraocular lens in the phacoemulsiphication diagnosed by ultrasonic biomicroscopy and its relationship to the postsurgical refractive surprise. METHODS: A prospective and descriptive study was performed in a sample of 176 eyes from 100 patients, who had been operated on from cataract with phacoemulsiphication using Pre Chop technique in the Ocular Microsurgery Service of "Ramón Pando Ferrer" Cuban Institute of Ophthalmology". The effective position of their intraocular lens diagnosed by ultrasonic biomicroscopy in the phacoemulsiphication and their relationship to the post surgery refractive surprise was determined. RESULTS: Most of the studied patients were older adult males. The ultrasonic biomicroscopy diagnosed the effective position of the intraocular lens in sac-sulcus to achieve the best postoperative corrected visual acuity in all the studied groups. The distance from the posterior face of the iris to the intraocular lens found in patients with intraocular lens in capsular sac showed a constant value. Most of the normocorrected patients had their intraocular lens in the capsular sac whereas the intraocular lens located in sac-sulcus position, whose haptics exhibited bigger angle, had bigger postoperative average cylinder, no significant differences were found among the postoperative average cylinders. CONCLUSIONS: The importance of the ultrasonic biomicroscopy is demonstrated in the determining the position of the intraocular lens in the surgical patients. The location of the intraocular lens is decisive in the postoperative refractive defect; bigger postoperative cylinder was more often found in the sac-sulcus position

Details

Language :
Spanish; Castilian
ISSN :
08642176 and 15613070
Volume :
23
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Revista Cubana de Oftalmología
Publication Type :
Academic Journal
Accession number :
edsdoj.2f2827ac9b043d68ecac0365e3c24a4
Document Type :
article