Back to Search
Start Over
Equivalence of laboratory-developed test and PD-L1 IHC 22C3 pharmDx across all combined positive score indications.
- Source :
- PLoS ONE, Vol 18, Iss 6, p e0285764 (2023)
- Publication Year :
- 2023
- Publisher :
- Public Library of Science (PLoS), 2023.
-
Abstract
- We conducted an analysis across multiple PD-L1 combined positive score (CPS) indications to establish concordance of a 22C3 antibody-based laboratory-developed test (LDT) on the Ventana BenchMark XT or BenchMark ULTRA platform and the regulatory-approved PD-L1 IHC 22C3 pharmDx in cervical cancer (CC), esophageal squamous cell carcinoma (ESCC), head and neck squamous cell carcinoma (HNSCC), triple-negative breast cancer (TNBC), and urothelial carcinoma (UC). Tumor specimens from each tumor type were stained with 22C3 antibody and scored using the 22C3 antibody-based LDT, and scores were compared with those using PD-L1 IHC 22C3 pharmDx. PD-L1 status was measured by the pathologist using CPS as a continuous score and using clinically relevant cutoffs (CC, ≥1 and ≥10; HNSCC, ≥1 and ≥20; ESCC, TNBC, and UC, ≥10). The agreement between the BenchMark platforms and PD-L1 IHC 22C3 pharmDx was assessed by intraclass correlation coefficient (ICC) and a contingency table for clinical interpretation. A total of 522 samples were evaluated for the pan-tumor analysis (CC, n = 77; ESCC, n = 80; HNSCC, n = 126; TNBC, n = 118, UC, n = 121). Most clinical interpretations of PD-L1 status were concordant between the BenchMark XT and PD-L1 IHC 22C3 pharmDx for all five tumor types with regard to negative percentage agreement (NPA; 83-97%), positive percentage agreement (PPA; 86-100%), and overall percentage agreement (OPA; 90-97%); the ICC by tumor type was high (≥0.88). Importantly, the pan-tumor ICC was 0.95 (95% CI 0.94-0.96). Thirty additional TNBC samples were evaluated using the BenchMark ULTRA and PD-L1 IHC 22C3 pharmDx; the NPA, PPA, and OPA were 100%. The 22C3 antibody-based LDT on Ventana BenchMark XT and BenchMark ULTRA platforms demonstrated high concordance with the regulatory-approved PD-L1 IHC 22C3 pharmDx across multiple tumor types. These findings suggest the comparability of PD-L1 IHC 22C3 pharmDx with an LDT based on the 22C3 antibody.
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 18
- Issue :
- 6
- Database :
- Directory of Open Access Journals
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.2e8bba0000141c7b1193adf1162a63a
- Document Type :
- article
- Full Text :
- https://doi.org/10.1371/journal.pone.0285764