Back to Search Start Over

Effect on postoperative visual quality with modified ABC design aspheric IOL implantation of cataract patients

Authors :
Hong-Gang Wang
Juan Luo
Yi-Ping Hu
Yu-Qi Liu
Jin-Song Zhang
Jing Wang
Source :
Guoji Yanke Zazhi, Vol 22, Iss 7, Pp 1097-1102 (2022)
Publication Year :
2022
Publisher :
Press of International Journal of Ophthalmology (IJO PRESS), 2022.

Abstract

AIM: To evaluate the visual quality of patients after modified design aspheric balance curve(ABC)with intraocular lens(IOL)implantation, and to analyze the influencing factors of clinical IOL selection and guide the patient's IOL selection plan. METHODS: A prospective case-control study was conducted in 67 patients(74 eyes)with simple cataract underwent phacoemulsification and foldable aspheric IOL implantation, and 23 eyes in the observation group were implanted with modified design IOL(HOYA Vivinex XY1 group), the control group was implanted with 51 eyes of traditional design IOL(Tecnis ZCB00 group with 27 eyes, IQ SN60WF group with 24 eyes). The uncorrected visual acuity, the best corrected visual acuity, total ocular spherical aberration(SA)and coma under different pupil diameters(3, 4, 5, 6mm), and different pupil diameters(3, 4, 5mm)were measured 1wk and 1mo after operation, the modulation transfer function(MTF)curve, objective scattering index(OSI), intraocular scattered light value Log(s)and contrast sensitivity were obtained. Statistical analysis was performed on the obtained data.RESULTS: The uncorrected visual acuity and best corrected visual acuity at 1wk and 1mo after operation in the three groups were significantly improved compared with those before operation, there was no significant difference among groups(P>0.05). The difference of total ocular spherical aberration was statistically significant among the three groups with 5 and 6mm pupil diameter 1wk after operation(P=0.045, 0.037)and there were differences among three groups in pupil diameter of 6mm at 1mo after operation(P=0.042). Comparing the total ocular coma aberration, there were differences among the three groups at 1wk and 1mo after the operation at the pupil diameter of 5 and 6 mm(P0.05), and there were no statistical differences in objective scattering index, intraocular scattered light value Log(s)and contrast sensitivity among the three groups(P>0.05).CONCLUSION:The improved design of the modified Vivinex IOL can reduce the total ocular spherical aberration and coma, improve the visual quality, and provide a new method for the selection of aspheric IOL.

Details

Language :
English
ISSN :
16725123
Volume :
22
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Guoji Yanke Zazhi
Publication Type :
Academic Journal
Accession number :
edsdoj.2e7c527c2424622bfcb3cbfd61b6f67
Document Type :
article
Full Text :
https://doi.org/10.3980/j.issn.1672-5123.2022.7.06