Back to Search Start Over

Gamma-induced background in the KATRIN main spectrometer

Authors :
K. Altenmüller
M. Arenz
W.-J. Baek
M. Beck
A. Beglarian
J. Behrens
A. Berlev
U. Besserer
K. Blaum
F. Block
S. Bobien
T. Bode
B. Bornschein
L. Bornschein
H. Bouquet
T. Brunst
N. Buzinsky
S. Chilingaryan
W. Q. Choi
M. Deffert
P. J. Doe
O. Dragoun
G. Drexlin
S. Dyba
K. Eitel
E. Ellinger
R. Engel
S. Enomoto
M. Erhard
D. Eversheim
M. Fedkevych
J. A. Formaggio
F. M. Fränkle
G. B. Franklin
F. Friedel
A. Fulst
W. Gil
F. Glück
A. Gonzalez Ureña
R. Grössle
R. Gumbsheimer
M. Hackenjos
V. Hannen
F. Harms
N. Haußmann
F. Heizmann
K. Helbing
W. Herz
S. Hickford
D. Hilk
D. Hillesheimer
M. A. Howe
A. Huber
A. Jansen
C. Karl
J. Kellerer
N. Kernert
L. Kippenbrock
M. Klein
A. Kopmann
M. Korzeczek
A. Kovalík
B. Krasch
A. Kraus
M. Kraus
T. Lasserre
O. Lebeda
B. Lehnert
J. Letnev
A. Lokhov
M. Machatschek
A. Marsteller
E. L. Martin
S. Mertens
S. Mirz
B. Monreal
H. Neumann
S. Niemes
A. Osipowicz
E. Otten
D. S. Parno
A. Pollithy
A. W. P. Poon
F. Priester
P. C.-O. Ranitzsch
O. Rest
R. G. H. Robertson
C. Rodenbeck
M. Röllig
C. Röttele
M. Ryšavý
R. Sack
A. Saenz
L. Schimpf
K. Schlösser
M. Schlösser
L. Schlüter
M. Schrank
H. Seitz-Moskaliuk
V. Sibille
M. Slezák
M. Steidl
N. Steinbrink
M. Sturm
M. Suchopar
D. Tcherniakhovski
H. H. Telle
L. A. Thorne
T. Thümmler
N. Titov
I. Tkachev
N. Trost
K. Valerius
D. Vénos
R. Vianden
A. P. Vizcaya Hernández
M. Weber
C. Weinheimer
C. Weiss
S. Welte
J. Wendel
J. F. Wilkerson
J. Wolf
S. Wüstling
S. Zadoroghny
G. Zeller
Source :
European Physical Journal C: Particles and Fields, Vol 79, Iss 9, Pp 1-12 (2019)
Publication Year :
2019
Publisher :
SpringerOpen, 2019.

Abstract

Abstract The KATRIN experiment aims to measure the effective electron antineutrino mass $$m_{\overline{\nu }_e}$$ mν¯e with a sensitivity of $${0.2}\,{\hbox {eV}/\hbox {c}^2}$$ 0.2eV/c2 using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of $${0.006}\,{\hbox {count}/\hbox {s}}$$ 0.006count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.

Details

Language :
English
ISSN :
14346044 and 14346052
Volume :
79
Issue :
9
Database :
Directory of Open Access Journals
Journal :
European Physical Journal C: Particles and Fields
Publication Type :
Academic Journal
Accession number :
edsdoj.2d6d8933221342e4bbfb26878accf790
Document Type :
article
Full Text :
https://doi.org/10.1140/epjc/s10052-019-7320-4