Back to Search Start Over

Endovascular repair of aortic pathologies involving the aortic arch using castor stent-graft combined with in-vitro fenestration technology

Authors :
Zeng-Rong Luo
Jia-Xin Zhang
Zhong-Yao Huang
Liang-Wan Chen
Source :
BMC Cardiovascular Disorders, Vol 23, Iss 1, Pp 1-13 (2023)
Publication Year :
2023
Publisher :
BMC, 2023.

Abstract

Abstract Background Aortic arch pathologies are concerning clinical conditions with poor prognoses. The use of thoracic endovascular aortic repair (TEVAR) has been investigated to treat aortic arch pathologies. Nonetheless, cerebral blood flow regulation during endovascular aortic arch repair therapy remains challenging. Castor, a unique single-branched stent graft, has been proven effective for retaining the left subclavian artery (LSA). This study aimed to determine whether endovascular therapy for pathologies involving the aortic arch using Castor in combination with the in-vitro fenestration technique is promising, effective, and safe. Methods Eligible patients were enrolled between June 2018 and December 2021. All patients underwent TEVAR with an evaluated proximal landing zone for “Castor” located in Ishimaru zones 0–1. Moreover, the supra-aortic branches (SABs) were reconstructed using the Castor in combination with the in-vitro fenestration technique. Results Herein, 57 patients with aortic arch lesions were treated with Castor in combination with the in-vitro fenestration technique. Innominate artery and the left carotid artery (LCA) were reconstructed in 5 patients, LCA and left subclavian artery (LSA) were reconstructed in 22 patients, and the total SABs were effectively reconstructed in 30 patients (including a hybrid arch repair case). Among them (excluding a hybrid arch repair case) were in-vitro fenestration methodologies for LCA in 32 of 34 cases (2 switched to in-situ fenestration) and LSA in 51 of 56 cases (3 switched to in-situ fenestration and 2 converted to spring coil caulking); furthermore, LCA and LSA in-vitro fenestration were simultaneously successfully performed in 27 of 34 cases. There were no surgical-related neurological complications, and early mortality was estimated at 5.26%. At a mean follow-up of 3.75 months, computed tomography (CTA) images confirmed that each branch stent remained patent. There were no signs of endoleaks, migrative manifestations, or the need for secondary endovascular intervention or conversion to open surgical procedures. Conclusion Castor, in combination with in-vitro fenestration, reflects a feasible, efficient procedure for re-developing SABs.

Details

Language :
English
ISSN :
14712261
Volume :
23
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Cardiovascular Disorders
Publication Type :
Academic Journal
Accession number :
edsdoj.2c7e3771de394e19b9ac8db212dc22de
Document Type :
article
Full Text :
https://doi.org/10.1186/s12872-023-03138-6