Back to Search Start Over

Punching resistance of internal slab-column connections with double-headed shear studs

Authors :
M. H. Oliveira
M. J. M. Pereira Filho
D. R. C. Oliveira
M. P. Ferreira
G. S. S. A. Melo
Source :
Revista IBRACON de Estruturas e Materiais, Vol 6, Iss 5, Pp 681-714
Publisher :
Instituto Brasileiro do Concreto (IBRACON).

Abstract

Punching shear is a brittle failure mode that may occur in slab-column connections, which may be prevented by using shear reinforcement in the slab-column connection. This paper presents comparisons between experimental results of 36 tests in internal slab-column connections with double- headed shear studs, which are largely used in North America, Europe and Asia, with theoretical results using recommendations presented by ACI 318, NBR6118, Eurocode 2 and also the Critical Shear Crack Theory (CSCT).Considering the database used it is possible to observe that ACI 318 presents conservative trends, whereas NBR 6118 showed a low coefficient of variation, but with a large number of unsafe results. Both Eurocode 2 and CSCT showed satisfactory results with Eurocode 2 presenting slightly higher performance.

Details

Language :
English
ISSN :
19834195
Volume :
6
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Revista IBRACON de Estruturas e Materiais
Publication Type :
Academic Journal
Accession number :
edsdoj.21c8b7f504ab691364e6b3274ea09
Document Type :
article
Full Text :
https://doi.org/10.1590/S1983-41952013000500002