Surface roughness of resin-based composites Subjected to professional prophylaxis

Authors :
João Lacerda Neto
José Alejandro Castro González
Matheus de Paula Costa
Leticia de Andrade Balardini
Marissol Fernandes Oliveira
Marina Amaral
Rayssa Ferreira Zanatta
Source :
Revista da Faculdade de Odontologia de Porto Alegre, Vol 64, Pp e130840-e130840 (2023)
Publication Year :
2023
Publisher :
Universidade Federal do Rio Grande do Sul. Faculdade de Odontologia, 2023.

Abstract

Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH – nanohybrid composite with regular viscosity (Vittra APS); BF – high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS – nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB – prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP – prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p

Details

Language :
English, Portuguese
ISSN :
05661854 and 21770018
Volume :
64
Database :
Directory of Open Access Journals
Journal :
Revista da Faculdade de Odontologia de Porto Alegre
Publication Type :
Academic Journal
Accession number :
edsdoj.204e5e5e069247698cce2e9ef623a4f3
Document Type :
article
Full Text :
https://doi.org/10.22456/2177-0018.130840