Back to Search Start Over

Evaluation of superficial xenograft volume estimation by ultrasound and caliper against MRI in a longitudinal pre-clinical radiotherapeutic setting.

Authors :
Daniel Roth
Marcella Safi
Oskar Vilhelmsson Timmermand
Evangelia Sereti
Malwina Molendowska
Michael Gottschalk
Anders Bjartell
Crister Ceberg
Filip Szczepankiewicz
Joanna Strand
Source :
PLoS ONE, Vol 19, Iss 7, p e0307558 (2024)
Publication Year :
2024
Publisher :
Public Library of Science (PLoS), 2024.

Abstract

BackgroundAccurate tumor volume estimation is important for evaluating the response to radionuclide therapy and external beam radiotherapy as well as to other pharmaceuticals. A common method for monitoring the growth of subcutaneous tumors in pre-clinical models and assessing the treatment response is to measure the tumor length and width by external calipers to estimate its volume. This procedure relies on an assumption of a spheroidal tumor shape wherein the tumor depth equals the width and can yield considerably inaccuracies. Ultrasound imaging is a non-invasive technique that can measure all three axes of the tumor and might be an alternative to caliper measurement with potentially greater accuracy and comparable ease-of-use and throughput. Both 2D and 3D ultrasound imaging are possible, the former offering short scan times without the need for anesthesia and heating-valuable factors for longitudinal studies in large animal cohorts. Nevertheless, tumor volume estimation accuracy by 2D ultrasound imaging has seen limited investigation. In this study we have evaluated the accuracy of tumor volume estimation by caliper and 2D ultrasound with comparisons to reference measurements by magnetic resonance imaging (MRI) in a pre-clinical model of prostate cancer treated with either external beam radiotherapy, radionuclide therapy, or no treatment.ResultsTumor volumes were measured longitudinally in 29 mice by caliper, ultrasound, and MRI before and after external beam radiotherapy, [177Lu]Lu-PSMA-617 radionuclide therapy, or no treatment. Caliper measurements had a marked bias, overestimating the tumor volumes by a median of 150% compared to MRI. Ultrasound measurements were markedly more accurate, with a median bias of -21% compared to MRI.ConclusionUltrasound imaging is a reliable and accurate method for tumor volume estimation in pre-clinical models of radiotherapy, whereas caliper measurements are prone to overestimation.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
19
Issue :
7
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.2028e8cd1b043768f6c41dd6ff82eaf
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0307558