Back to Search Start Over

STUDY ON STRUCTURE INFLUENCE FACTOR OF DIESEL ENGINE EXHAUST MANIFOLD THERMAL LOAD

Authors :
MA ZiYuan
BI YuHua
SHEN LiZhong
LEI Ji Lin
JIA DeWen
WU Tao
Source :
Jixie qiangdu, Vol 38, Pp 348-355 (2016)
Publication Year :
2016
Publisher :
Editorial Office of Journal of Mechanical Strength, 2016.

Abstract

Exhaust manifold is a main heated component of engine,which has poor working conditions. High levels of thermal load can lead to deformation even cracking,which affect its normal working and reliability and durability. Aiming at the high thermal load of a high pressure common rail diesel engine,different fluid-solid coupling models was built and the temperature distribution and thermal stress of the engine exhaust manifold was stimulated and the influence of different structural factors on the exhaust manifold thermal load was calculated and analyzed. Results show that: the maximum temperature of the exhaust manifold changed from 805. 2 ℃ to 820. 8 ℃ as the outlet length increased,the maximum temperature of the exhaust manifold changed from 805. 2 ℃ to 819. 4 ℃ as the outlet diameter increasing,and the maximum temperature of the exhaust manifold dropped to 784. 0 ℃ as the outlet transferred to the body symmetry position. Structure factors such as exhaust outlet position,outlet length and outlet diameter had a great influence on the exhaust manifold thermal load. The maximum thermal stress value was 326. 21 MPa of the case of 21 mm outlet length and 5 mm outlet diameter outlet with the non-symmetry outlet position; the minimum thermal stress value was 174. 1 MPa of the case of 19 mm outlet length and 5mm outlet diameter with the non-symmetry outlet position.

Details

Language :
Chinese
ISSN :
10019669
Volume :
38
Database :
Directory of Open Access Journals
Journal :
Jixie qiangdu
Publication Type :
Academic Journal
Accession number :
edsdoj.1f4ed4dd9bd64f948058465315df9bcc
Document Type :
article
Full Text :
https://doi.org/10.16579/j.issn.1001.9669.2016.02.024