Back to Search Start Over

Comparison of shear bond strength of orthodontic brackets bonded using two different hydrophilic primers: An in vitro study

Authors :
M Kumaraswamy Anand
Kaberi Majumder
Sundaram Venkateswaran
N Rengarajan Krishnaswamy
Source :
Indian Journal of Dental Research, Vol 25, Iss 2, Pp 191-196 (2014)
Publication Year :
2014
Publisher :
Wolters Kluwer Medknow Publications, 2014.

Abstract

Context: Salivary control and maintenance of a dry operating field is a prime requisite of orthodontic bonding. Moisture insensitive primer (MIP) with a clinical significant bond strength values have a better edge over the conventional hydrophobic bonding systems. Aim: The aim of this study is to investigate the effectiveness of two hydrophilic primers with respect to conventional hydrophobic primer by comparing their shear bond strength (SBS) and adhesive-failure locations after contamination with saliva and saliva substitute. Materials and Methods: A total of 150 extracted human premolars were randomly divided into five group s ; Group A (Transbond MIP/saliva substitute), Group B (Opal Primo/saliva substitute), Group C (Transbond MIP/natural saliva), Group D (Opal Primo/natural saliva), control group - Group E (Transbond XT/dry), adhesive-Transbond XT used for all five groups and bonded using stainless steel brackets. Shear forces were applied to the samples with a universal testing machine. SBSs was measured in megapascals. The mode of bond failure was determined using the adhesive remnant index (ARI). Results: The mean SBS produced by Transbond MIP was higher than Opal Primo, which was statistically significant according to one-way analysis of variance. Both the tested groups showed lesser bond strength values than Transbond XT (the control). ARI scores revealed that there was no statistically significant difference in the site of bond failure between study groups. ARI scores were found to be lower for study groups suggesting adhesive failure, compared to higher ARI scores for the control group suggesting cohesive failure. Conclusion: Transbond XT adhesive with Transbond MIP or Opal Primo have clinically acceptable bond strength in wet fields. Opal Primo is a viable option to use as a hydrophilic primer clinically.

Details

Language :
English
ISSN :
09709290 and 19983603
Volume :
25
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Indian Journal of Dental Research
Publication Type :
Academic Journal
Accession number :
edsdoj.1cd59bbb34834160bd994f79b7800ab4
Document Type :
article
Full Text :
https://doi.org/10.4103/0970-9290.135919