Back to Search Start Over

The small screw-apex distance is potentially associated with femoral head osteonecrosis in adults with femoral neck fractures treated by closed reduction and percutaneous 3 parallel cannulated screws

Authors :
Xiaoxiao Zhou
Shengyang Guo
Wenjun Pan
Linyuan Zhang
Houlin Ji
Yang Yang
Source :
BMC Musculoskeletal Disorders, Vol 25, Iss 1, Pp 1-8 (2024)
Publication Year :
2024
Publisher :
BMC, 2024.

Abstract

Abstract Objective Femoral neck fractures (FNFs) are among the most common fractures in elderly individuals. Surgery is the main treatment for FNFs, and osteonecrosis of the femoral head (ONFH) is one of the unacceptable complications. This study aimed to assess both the clinical and radiological outcomes in patients with FNFs treated with three parallel cannulated screws and to identify relationship between screws position and ONFH. Patients and methods A total of 100 patients who were treated with closed reduction and fixed with 3 parallel cannulated screws met the inclusion criteria between January 2014 and December 2020 at authors’ institution. The follow-up duration, age, sex, affected side, and injury-to-surgery interval were collected; the neck-shaft angle of both hips, screw-apex distance (SAD) and the tip-apex distance (TAD)were measured; and the Garden classification, quality of reduction and presence of ONFH were evaluated. Results The sample consisted of 37 males and 63 females, with 60 left and 40 right hips affected. The mean age of patients was 54.93 ± 12.24 years, and the mean follow-up was 56.3 ± 13.38 months. The overall incidence of ONFH was 13%. No significant difference was observed in the incidence of ONFH by affected side, age, fracture displacement, injury-to-surgery interval, neck-shaft angle deviation, or reduction quality. The SAD was significantly shorter in ONFH patients than in normal patients for all three screws (p = 0.02, 0.02, and 0.01, respectively). Conclusions The short SAD of all screws is associated with femoral head necrosis of FNFs treated with 3 cannulated screws. The short SAD indicated that screws malpositioning in the weight-bearing area of the femoral head, potentially harming the blood supply and compromising the anchorage of the primary compressive trabeculae in this region.

Details

Language :
English
ISSN :
14712474
Volume :
25
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Musculoskeletal Disorders
Publication Type :
Academic Journal
Accession number :
edsdoj.1bf35cb67c8d4e46b1c2d54a2845c1e7
Document Type :
article
Full Text :
https://doi.org/10.1186/s12891-024-07380-7