Back to Search Start Over

Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

Authors :
Kiessling Arndt H
Wood Jeffrey P
Doss Mirko
Moritz Anton
Source :
Journal of Cardiothoracic Surgery, Vol 6, Iss 1, p 136 (2011)
Publication Year :
2011
Publisher :
BMC, 2011.

Abstract

Abstract Background We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age < 55 years), either stentless bioprosthesis (CE Prima Plus n = 20) or MP (Edwards Mira n = 20) in group 2 (age 55-75 years) and either stentless (CE Prima Plus n = 20) or stented bioprosthesis (CE Perimount n = 20) in group 3 (age > 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs.

Details

Language :
English
ISSN :
17498090
Volume :
6
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Cardiothoracic Surgery
Publication Type :
Academic Journal
Accession number :
edsdoj.15bcacd93f3047a8a0da83d25f1e89e0
Document Type :
article
Full Text :
https://doi.org/10.1186/1749-8090-6-136