- Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL) power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG)/ALLEGRO BioGraph biometer (Wavelight., AG), and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG]) before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL), corneal refractive power (K1 and K2), and anterior chamber depth (ACD), power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0) with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P
- Subjects :
- Glaucoma
pressure-to-cornea index
visual field
Combined trabeculectomy
glaucoma tube shunt surgery
long-term results
ocular perfusion pressure
open-angle glaucoma
systemic hypertension
Anterior stromal opacities
femtosecond anterior lamellar keratoplasty
spectral domain optical coherence tomography
Anesthesia
cataract
phacoemulsification
randomized control trail
Cataract
intraocular lens
optical low-coherence reflectometry
partial coherence interferometry
Ophthalmology
RE1-994
Subjects
Details
- Language :
- English
- ISSN :
- 03014738 and 19983689
- Volume :
- 62
- Issue :
- 9
- Database :
- Directory of Open Access Journals
- Journal :
- Indian Journal of Ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.157e292b234149dd92a2f7279df59af4
- Document Type :
- article
- Full Text :
- https://doi.org/10.4103/0301-4738.143930