Back to Search Start Over

Midterm outcomes of aortic valve replacement using a rapid-deployment valve for aortic stenosis: TRANSFORM trialCentral MessagePerspective

Authors :
S. Chris Malaisrie, MD
Mubashir A. Mumtaz, MD
Glenn R. Barnhart, MD
Randolph Chitwood, MD
William H. Ryan, MD
Kevin D. Accola, MD
Himanshu J. Patel, MD
Y. Joseph Woo, MD
Todd M. Dewey, MD
Konstantinos Koulogiannis, MD
Michael P. Dorsey, MD
Eugene A. Grossi, MD
Source :
JTCVS Open, Vol 17, Iss , Pp 55-63 (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory–adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory–adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

Details

Language :
English
ISSN :
26662736
Volume :
17
Issue :
55-63
Database :
Directory of Open Access Journals
Journal :
JTCVS Open
Publication Type :
Academic Journal
Accession number :
edsdoj.138a8df3dd55470aa985a61d69dd3407
Document Type :
article
Full Text :
https://doi.org/10.1016/j.xjon.2023.10.034