Midterm outcomes of aortic valve replacement using a rapid-deployment valve for aortic stenosis: TRANSFORM trialCentral MessagePerspective
- Source :
- JTCVS Open, Vol 17, Iss , Pp 55-63 (2024)
- Publication Year :
- 2024
- Publisher :
- Elsevier, 2024.
-
Abstract
- Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory–adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory–adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.
Details
- Language :
- English
- ISSN :
- 26662736
- Volume :
- 17
- Issue :
- 55-63
- Database :
- Directory of Open Access Journals
- Journal :
- JTCVS Open
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.138a8df3dd55470aa985a61d69dd3407
- Document Type :
- article
- Full Text :
- https://doi.org/10.1016/j.xjon.2023.10.034