Back to Search Start Over

Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications

Authors :
Sang Hyun Cho
Hyun Jung Yoon
Young Lee
Injoong Kim
Je Ryung Gil
Yeo Jin Kim
Source :
Diagnostics, Vol 14, Iss 21, p 2441 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Background: Fluoroscopy-guided PTNB for fluoroscopy-identifiable lung lesions has been suggested as a useful method for the pathological diagnosis of lung lesions; however, it is lacking in accuracy and safety compared to CT-guided PTNB. Thus, we aimed to investigate the diagnostic accuracy and complications of fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) with the aid of pre-procedural planning cone-beam computed tomography (CBCT) in order to take advantage of their respective strengths. Methods: A total of 255 fluoroscopy-guided PTNBs with the aid of planning CBCT were performed. Pre-procedural planning CBCT was conducted to calculate the shortest length from the skin puncture site to the margin of the target lesion for the needle trajectory. No intra-procedural CBCT was performed. The diagnostic performance of fluoroscopy-guided PTNB with the aid of planning CBCT was calculated. The prognostic factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 97.3%, 88.0%, 90.9%, 100%, and 62.5%, respectively. There were 29 diagnostic failures (11.8%), and the multivariable analysis showed that a longer lesion depth on CBCT and a shorter specimen length were each associated with diagnostic failure (p = 0.010 and 0.012, respectively). Complications occurred in 34 PTNBs (13.3%). The multivariable analysis showed that an increased total number of biopsies per lesion, a longer length of lung aeration via needle insertion, a smaller lesion size on CT imaging (≤20 mm), and the presence of an air bronchogram were associated with the occurrence of complications (p = 0.027, Conclusions: Excellent diagnostic accuracy was obtained by fluoroscopy-guided PTNB with the aid of planning CBCT. Compared to that of CT- or CBCT-guided PTNB, the procedure-related complication rate was acceptably low, but the radiation dose to patients could be potentially reduced.

Details

Language :
English
ISSN :
20754418
Volume :
14
Issue :
21
Database :
Directory of Open Access Journals
Journal :
Diagnostics
Publication Type :
Academic Journal
Accession number :
edsdoj.1373c00e4199496fa08caa11afd483e2
Document Type :
article
Full Text :
https://doi.org/10.3390/diagnostics14212441