Back to Search Start Over

Stability indicating high performance thin layer chromatography method development and validation for quantitative determination of tetracycline hydrochloride in tetracycline hydrochloride active pharmaceutical ingredient (API) and its dosage forms

Authors :
Misganaw Gashaw
Thomas Layloff
Ariaya Hymete
Ayenew Ashenef
Source :
BMC Chemistry, Vol 18, Iss 1, Pp 1-16 (2024)
Publication Year :
2024
Publisher :
BMC, 2024.

Abstract

Abstract Simple, quick, cost-effective, and environmentally friendly analytical methods for quality assurance and control roles for different medicines, including Tetrcyclines, are most significantly needed. Also, different thin layer chromatography (TLC)-based methods for tetracycline identification exist, but high performance thin layer chromatography methods based on modern state- of- the art equipment are still nonexistent. Thus, in this study, analytical method development and verification were done by high performance thin layer chromatography (HPTLC) (using an automated equipment model) using glass plates coated with silica gel 60 F254 after treating with 10% Na2EDTA. Validation was carried out according to International Council for Harmonization (ICH) guidelines. A mobile phase formed from ethyl acetate, acetonitrile, methanol, and 1% aqueous ammonia in the composition of 4.4:19.6:10:6 volume to volume ratio (V/V) was used. Rf value, percentage recoveries, linearity ranges, limit of detection (LOD), and limit of quantitation (LOQ) for the developed HPTLC method were 0.28, 100.83–106.25%, 160–560 ng/band (r2 values of 0.9999), 31.9 ng/band, and 96.7 ng/band, respectively. The results of the sample assays conducted using the new method and the United States Pharmacopoeia (USP) high performance liquid chromatography (HPLC) method were 91.59% to 108.3% and 90.83% to 102.85%, respectively. The F test for the aforementioned methods was 2.01, which is smaller than the tabulated F value of 5.05 with 5 degrees of freedom at a 95% confidence range, proving that the newly developed HPTLC and HPLC pharmacopoeial methods can be used interchangeably.The newly developed HPTLC method is easy, economical, specific, accurate, and roboust, thus it can be employed in a range of settings that require quality control and assurance activities of tetracycline hydrochloride (TC-HCl) in bulk and ointment dosage forms.

Details

Language :
English
ISSN :
2661801X
Volume :
18
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Chemistry
Publication Type :
Academic Journal
Accession number :
edsdoj.0e1fa01f3ddb4abb9b1b17be66f027cd
Document Type :
article
Full Text :
https://doi.org/10.1186/s13065-024-01183-6