Back to Search Start Over

Optimization-derived blood input function using a kernel method and its evaluation with total-body PET for brain parametric imaging

Authors :
Yansong Zhu
Quyen Tran
Yiran Wang
Ramsey D. Badawi
Simon R. Cherry
Jinyi Qi
Shiva Abbaszadeh
Guobao Wang
Source :
NeuroImage, Vol 293, Iss , Pp 120611- (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Dynamic PET allows quantification of physiological parameters through tracer kinetic modeling. For dynamic imaging of brain or head and neck cancer on conventional PET scanners with a short axial field of view, the image-derived input function (ID-IF) from intracranial blood vessels such as the carotid artery (CA) suffers from severe partial volume effects. Alternatively, optimization-derived input function (OD-IF) by the simultaneous estimation (SIME) method does not rely on an ID-IF but derives the input function directly from the data. However, the optimization problem is often highly ill-posed. We proposed a new method that combines the ideas of OD-IF and ID-IF together through a kernel framework. While evaluation of such a method is challenging in human subjects, we used the uEXPLORER total-body PET system that covers major blood pools to provide a reference for validation. Methods: The conventional SIME approach estimates an input function using a joint estimation together with kinetic parameters by fitting time activity curves from multiple regions of interests (ROIs). The input function is commonly parameterized with a highly nonlinear model which is difficult to estimate. The proposed kernel SIME method exploits the CA ID-IF as a priori information via a kernel representation to stabilize the SIME approach. The unknown parameters are linear and thus easier to estimate. The proposed method was evaluated using 18F-fluorodeoxyglucose studies with both computer simulations and 20 human-subject scans acquired on the uEXPLORER scanner. The effect of the number of ROIs on kernel SIME was also explored. Results: The estimated OD-IF by kernel SIME showed a good match with the reference input function and provided more accurate estimation of kinetic parameters for both simulation and human-subject data. The kernel SIME led to the highest correlation coefficient (R = 0.97) and the lowest mean absolute error (MAE = 10.5 %) compared to using the CA ID-IF (R = 0.86, MAE = 108.2 %) and conventional SIME (R = 0.57, MAE = 78.7 %) in the human-subject evaluation. Adding more ROIs improved the overall performance of the kernel SIME method. Conclusion: The proposed kernel SIME method shows promise to provide an accurate estimation of the blood input function and kinetic parameters for brain PET parametric imaging.

Details

Language :
English
ISSN :
10959572
Volume :
293
Issue :
120611-
Database :
Directory of Open Access Journals
Journal :
NeuroImage
Publication Type :
Academic Journal
Accession number :
edsdoj.0dca946ab3d74160b52fc16cc5bef7ec
Document Type :
article
Full Text :
https://doi.org/10.1016/j.neuroimage.2024.120611