Back to Search Start Over

Calculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes

Authors :
M. Malík
J. Primas
V. Kopecký
M. Svoboda
Source :
AIP Advances, Vol 4, Iss 1, Pp 017137-017137-7 (2014)
Publication Year :
2014
Publisher :
AIP Publishing LLC, 2014.

Abstract

This paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect). A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches.

Subjects

Subjects :
Physics
QC1-999

Details

Language :
English
ISSN :
21583226
Volume :
4
Issue :
1
Database :
Directory of Open Access Journals
Journal :
AIP Advances
Publication Type :
Academic Journal
Accession number :
edsdoj.0d516d00700e4e8fabebf050b4be7e00
Document Type :
article
Full Text :
https://doi.org/10.1063/1.4864181