Back to Search Start Over

The CX-DZ-II intelligent electronic stimulator for neck pain caused by cervical spondylosis: A two-center, randomized, controlled, and non-inferiority trial

Authors :
Liping Chen
Dehua Li
Jing Xu
Hao Liang
Ya Zhang
Yulan Ren
Fanrong Liang
Source :
Frontiers in Neuroscience, Vol 16 (2022)
Publication Year :
2022
Publisher :
Frontiers Media S.A., 2022.

Abstract

BackgroundElectroacupuncture (EA) has been commonly used for the management of neck pain caused by cervical spondylosis (NPCS); however, current electrical instruments have limitations on intelligence, digitalization, and visualization. The intelligent electronic stimulator (CX-DZ-II) is a digital device with an evidence-based diagnosis and treatment system. This study aimed to investigate the efficacy and safety of the CX-DZ-II intelligent EA instrument for NPCS.Materials and MethodsA total of 164 patients with NPCS [mean age (SD), 49.48 (13.47) years] were randomly assigned to receive 8 sessions (over 2 weeks) EA of the intelligent electronic stimulator (CX-DZ-II) or the regular electronic stimulator (SDZ-II). The primary outcome was the change of the visual analog scale (VAS) from baseline to 2 weeks of treatment. Secondary outcomes included mean scores of the VAS after each treatment in 1 week, responder rate, drug-usage rate of non-steroidal antipyretic analgesics (NSAAs), the occurrence rate of adverse events (AEs), proportions of apparatus with defect during treatment, and excellent rate of apparatus.ResultsThe intelligent electronic stimulator (CX-DZ-II) was non-inferior to the regular electronic stimulator (SDZ-II) for changes from baseline in the VAS [3.36 vs. 3.23, with a difference of 0.17 (95% CI, −0.36 to 0.69), P < 0.025 for non-inferiority]. No between-group differences were found in outcomes of VAS in 1 week, overall responders, and drug-usage rate of NSAAs. The defect rate and excellent rate of the instrument were similar in the CX-DZ-II and SDZ-II groups. Adverse events occurred in 9 (10.84%) patients in the CX-DZ-II group and 4 (5.00%) patients in the SDZ-II group.ConclusionThe intelligent electronic stimulator (CX-DZ-II) was non-inferior to the regular electronic stimulator (SDZ-II) in relieving neck pain. The intelligent electronic stimulator (CX-DZ-II) is a promising non-inferior alternative instrument for NPCS.Clinical Trial Registration[https://clinicaltrials.gov/], identifier [NCT030 05301].

Details

Language :
English
ISSN :
1662453X
Volume :
16
Database :
Directory of Open Access Journals
Journal :
Frontiers in Neuroscience
Publication Type :
Academic Journal
Accession number :
edsdoj.0b80f34c98214a64aa03ee6b4a2adaf3
Document Type :
article
Full Text :
https://doi.org/10.3389/fnins.2022.910574