Back to Search Start Over

The five times sit-to-stand test: safety, validity and reliability with critical care survivors’s at ICU discharge

Authors :
Thiago Araújo de Melo
Fernando Silva Guimarães
José Roberto Lapa e Silva
Source :
Archives of Physiotherapy, Vol 13, Iss 1, Pp 1-9 (2022)
Publication Year :
2022
Publisher :
AboutScience Srl, 2022.

Abstract

Abstract Background The Five Times Sit-to-Stand Test (FTSST) has been found reliable, safe and valid for measuring healthy adults’ lower limb muscle strength and for determining balance control, fall risk, and exercise capacity among older examinees. We believe that the FTSST has the potential to be a straightforward, low cost and valuable tool for identifying muscle disability and functional status following critical illness. The aim of our study was to establish the applicability, safety, and psychometric qualities of FTSST in patients at Intensive Care Unit (ICU) discharge. Methods In our study applicability was determined by assessing the percentage of patients who could perform the test at ICU discharge. Safety was assessed by examining data regarding any exacerbated haemodynamic and respiratory responses or adverse events associated with the test. For assessing FTSST reliability, intraclass correlation coefficients (ICCs), standard error of measurement (SEM) and Bland-Altman plot were used. For assessing concurrent validity handgrip strength, ICU length of stay, duration of invasive ventilation, Simplified Acute Physiology Score 3 (SAPS3) and age variables were used. For investigating predictive validity, correlations between the FTSST and measures of hospital length of stay and functional independence were evaluated. Results Only 30% of ICU survivors (n = 261 out of 817) were eligible to perform the FTSST and 7% of patients who performed the test (n = 10 out of 142) presented adverse events. Both inter (ICC 0.92 CI95% 0.89–0.94) and intra-rater (ICC 0.95 CI95% 0.93–0.96) reliability were excellent and higher scores were associated with lower muscle strength, longer hospital stay and greater functional impairment at hospital discharge in adult survivors of critical diseases. Conclusion Our results suggest that the FTSST may be applicable only to high-functioning critical care survivors. In this specifical population, FTSST is a safe, easy to perform, valid and reliable measure that can be applied to fall risk and functional recovery management.

Details

Language :
English
ISSN :
20570082
Volume :
13
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Archives of Physiotherapy
Publication Type :
Academic Journal
Accession number :
edsdoj.0a65c11faa4841a9b94f384dd2f572
Document Type :
article
Full Text :
https://doi.org/10.1186/s40945-022-00156-z