Back to Search Start Over

Film Cooling Effectiveness Data for Simple Injection Geometries: A Collection of Three-Axis Plots

Authors :
L. D. Stone
R. J. Goldstein
Source :
International Journal of Rotating Machinery, Vol 1, Iss 1, Pp 73-81 (1994)
Publication Year :
1994
Publisher :
Hindawi Limited, 1994.

Abstract

A three-axis plot of laterally averaged film cooling effectiveness versus blowing rate and versus dimensionless distance downstream is a sufficiently compact representation of film cooling effectiveness data for injection through a row of holes or two rows of holes to enable easy, global comparisons among a variety of data sets. By plotting data from several film cooling studies conducted at the University of Minnesota, the dominant roles played by density ratio, hole spacing, and surface curvature become apparent. It is also seen that a slot-plate prediction/correlation from two-dimensional film cooling studies makes an excellent standard of comparison for all film cooling studies, even though the more commonly encountered (two-axis) comparisons using standardized nondimensional parameters do not usually suggest this.

Details

Language :
English
ISSN :
1023621X
Volume :
1
Issue :
1
Database :
Directory of Open Access Journals
Journal :
International Journal of Rotating Machinery
Publication Type :
Academic Journal
Accession number :
edsdoj.09d204219fbf4a648821932a7848c7d9
Document Type :
article
Full Text :
https://doi.org/10.1155/S1023621X94000072