Back to Search Start Over

Preclassification of Broadband and Sparse Infrared Data by Multiplicative Signal Correction Approach

Preclassification of Broadband and Sparse Infrared Data by Multiplicative Signal Correction Approach

Authors :
Hafeez Ur Rehman
Valeria Tafintseva
Boris Zimmermann
Johanne Heitmann Solheim
Vesa Virtanen
Rubina Shaikh
Ervin Nippolainen
Isaac Afara
Simo Saarakkala
Lassi Rieppo
Patrick Krebs
Polina Fomina
Boris Mizaikoff
Achim Kohler
Source :
Molecules, Vol 27, Iss 7, p 2298 (2022)
Publication Year :
2022
Publisher :
MDPI AG, 2022.

Abstract

Preclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures. Hence, a preclassification approach to separate infrared spectra for sparse data is needed. In this study, we propose a preclassification approach based on Multiplicative Signal Correction (MSC). The MSC approach was applied on human and the bovine knee cartilage broadband Fourier Transform Infrared (FTIR) spectra and on a sparse data subset comprising of only seven wavelengths. The goal of the preclassification was to separate spectra with analyte-rich signals (i.e., cartilage) from spectra with analyte-poor (and high-matrix) signals (i.e., water). The human datasets 1 and 2 contained 814 and 815 spectra, while the bovine dataset contained 396 spectra. A pure water spectrum was used as a reference spectrum in the MSC approach. A threshold for the root mean square error (RMSE) was used to separate cartilage from water spectra for broadband and the sparse spectral data. Additionally, standard noise-to-ratio and principle component analysis were applied on broadband spectra. The fully automated MSC preclassification approach, using water as reference spectrum, performed as well as the manual visual inspection. Moreover, it enabled not only separation of cartilage from water spectra in broadband spectral datasets, but also in sparse datasets where manual visual inspection cannot be applied.

Details

Language :
English
ISSN :
14203049
Volume :
27
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Molecules
Publication Type :
Academic Journal
Accession number :
edsdoj.06b96c0db4d5bade7568c82eea9e1
Document Type :
article
Full Text :
https://doi.org/10.3390/molecules27072298