Abstract

Abstract Purpose: We developed a contrast sensitivity test that considers an integrative approach of spatial and temporal frequencies to evaluate the psychophysical channels in processing two-dimensional stimulus for clinical use. Our new procedure provides a more efficient isolation of the magnocellular and parvocellular visual pathways supporting spatiotemporal contrast sensitivity processing. Methods: We evaluated 36 participants of both sexes aged 18–30 years with 20/20 or better best-corrected visual acuity. Two spatial frequencies (0.5 cycles per degree [cpd] and 10 cpd), being in one of the three temporal frequencies (0.5 cycle per second [cps], 7.5 cps, and 15 cps), were presented in a high-resolution gamma corrected monitor. A two-alternative forced-choice procedure was conducted, and the staircase method was used to calculate the contrast sensitivity. Reliability was assessed using a retest procedure within a month ( ± 5 days) under the same conditions. Results: Results showed statistical significance in 0.5 cpd and 10 cpd spatial frequencies for 0.5 cps (F = 77.36; p < 0.001), 7.5 cps (F = 778.37; p < 0.001), and 15 cps (F = 827.23; p < 0.001) with a very high (η ² = 0.89) effect size. No statistical differences were found between the first and second sessions for all spatial frequencies. For reliability, a significantly high correlation and high internal consistency were found in all spatiotemporal conditions. The limits were calculated for normality. Conclusion: We developed an approach to investigate the spatiotemporal integration of contrast sensitivity designed for clinical purposes. The relative contribution of the low spatial frequencies/high temporal frequencies and the high spatial frequencies/low temporal frequencies of the psychophysical channels can also be evaluated separately.

Details

Language :
English
ISSN :
20082010 and 2008322X
Volume :
17
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Ophthalmic & Vision Research
Publication Type :
Academic Journal
Accession number :
edsdoj.0562a3a868124128befca0038d067c1e
Document Type :
article
Full Text :
https://doi.org/10.18502/jovr.v17i1.10172