Back to Search Start Over

Prospects of low-modulus alloys of the TI-(15-20)NB-(5-10)TA system for engineering implants used in traumatology and orthopedics. A preclinical study

Authors :
Sergey A. Oshkukov
Alexander S. Baikin
Anatoly G. Galkin
Polina A. Glazkova
Dmitry A. Shavyrin
Victor P. Voloshin
Konstantin V. Shevyrev
Tatyana A. Biryukova
Ivan M. Dementiev
Elena N. Petritskaya
Alexey G. Kolmakov
Elena O. Nasakina
Sergey V. Konushkin
Mikhail A. Kaplan
Konstantin V. Sergienko
Mikhail A. Sevostyanov
Source :
Гений oртопедии, Vol 28, Iss 6, Pp 830-836 (2022)
Publication Year :
2022
Publisher :
Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics, 2022.

Abstract

Aim Study of mechanical and biological properties of five variants of alloys of the Ti-Nb-Ta system. Materials and methods Five alloys were obtained from the system: Ti-(15-20)Nb-(5-10)Ta (at. %). Their mechanical tests were carried out by stretching on the INSTRON 3382 universal testing machine in accordance with GOST 1497-84. The biological properties of the resulting alloys were evaluated in in vivo experiments (implantation surgery) on white outbred male JCR mice. Histological study of the tissues of the limb with an implant, kidneys and liver was carried out at three time points: at 1, 4, 12 weeks after surgery, which corresponds to the early, middle and late phases after implantation. Results The samples showed ductility from 11.5 % to 14.6 %, strength from 549 to 673 MPa and Young's modulus from 42 to 50 GPa. The yield strength also varied depending on the composition of the alloy within 188 – 572 MPa. The inflammatory reaction was the least pronounced in the groups with Ti-20Nb-5Ta and Ti-15Nb-10Ta alloys implanted. Discussion Compared to the widely used TiAl6V4 alloy, the obtained alloys approximately correspond in terms of plasticity and have approximately 2 times lower Young's modulus, which should lead to better biomechanical compatibility between the implant and the surrounding biological tissues, preventing the effect of protection against stress and, accordingly, bone resorption. The relatively low tensile strength of the obtained alloys does not reduce the above-mentioned advantage over TiAl6V4, since this strength is quite sufficient for the proposed application. Histological study after 1, 4 and 12 weeks showed that the intensity of the local inflammatory reaction due to new alloys is higher than with the use of TiAl6V4, which requires further study and could be associated with a small sample size. Conclusions The way to create titanium alloys with a low Young's modulus may solve the problem of biomechanical compatibility of the implant with the surrounding tissues. The obtained and described alloys of the Ti-Nb-Ta system showed the neceary mechanical and, according to the initial assessment, acceptable biological properties that require further broader research.

Details

Language :
English, Russian
ISSN :
10284427 and 2542131X
Volume :
28
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Гений oртопедии
Publication Type :
Academic Journal
Accession number :
edsdoj.052b8d8f6a443e38e510dbffa184707
Document Type :
article
Full Text :
https://doi.org/10.18019/1028-4427-2022-28-6-830-836