Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT

Authors :
Achala Donuru
Tetsuro Araki
Farouk Dako
Jaydev K. Dave
Raul Porto Perez
Dongming Xu
Arun C. Nachiappan
Eduardo Mortani Barbosa, Jr
Peter Noel
Harold Litt
Friedrich Knollman
Source :
European Journal of Radiology Open, Vol 11, Iss , Pp 100538- (2023)
Publication Year :
2023
Publisher :
Elsevier, 2023.

Abstract

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p