Back to Search Start Over

Ultrasonographic Analysis of Optimal Needle Placement for Extensor Indicis

Authors :
Jin Young Kim
Hyun Seok
Sang-Hyun Kim
Yoon-Hee Choi
Jun Young Ahn
Seung Yeol Lee
Source :
Annals of Rehabilitation Medicine, Vol 44, Iss 6, Pp 450-458 (2020)
Publication Year :
2020
Publisher :
Korean Academy of Rehabilitation Medicine, 2020.

Abstract

Objective To determine the most optimal needle insertion point of extensor indicis (EI) using ultrasound. Methods A total 80 forearms of 40 healthy volunteers were recruited. We identified midpoint (MP) of EI using ultrasound and set MP as optimal needle insertion point. The location of MP was suggested using distances from landmarks. Distance from MP to medial border of ulna (MP-X) and to lower margin of ulnar head (MP-Y) were measured. Ratios of MP-X to Forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated. In cross-sectional view, depth of MP (Dmp), defined as middle value of superficial depth (Ds) and deep depth (Dd) was measured and suggested as proper depth of needle insertion. Results Mean MP-X was 1.37±0.14 cm and mean MP-Y was 5.50±0.46 cm. Mean X ratio was 8.10±0.53 and mean Y ratio was 22.15±0.47. Mean Dmp was 7.63±0.96 mm. Conclusion We suggested that novel optimal needle insertion point of the EI. It is about 7.6 mm in depth at about 22% of the forearm length proximal from the lower margin of the ulnar head and about 8.1% of the forearm circumference radial from medial border of ulna.

Details

Language :
English
ISSN :
22340645 and 22340653
Volume :
44
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Annals of Rehabilitation Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.0427a84ecf8454d8ac5c87c0ebf4f1d
Document Type :
article
Full Text :
https://doi.org/10.5535/arm.20035