Establishing the acceptability of a brief patient reported outcome measure and feasibility of implementing it in a breast device registry – a qualitative study

Authors :
Sze Ng
Maggie Kirkman
Jane Fisher
Andrea Pusic
Emily Parker
Rodney D. Cooter
Elisabeth Elder
Colin Moore
John McNeil
Ingrid Hopper
Source :
Journal of Patient-Reported Outcomes, Vol 3, Iss 1, Pp 1-8 (2019)
Publication Year :
2019
Publisher :
SpringerOpen, 2019.

Abstract

Abstract Background To examine the acceptability of a Patient Reported Outcome Measure (PROM) that assesses perceptions and experiences of implants for breast reconstruction or augmentation, and the feasibility of implementing it in the Australian Breast Device Registry (ABDR). Methods The BREAST-Q Implant Surveillance (BREAST-Q IS) is a 5-question PROM derived from the BREAST-Q questionnaire. It assesses perceptions of breast appearance and sensation, and experiences of pain. Breast implant recipients (recruited via community networks, social media and notices in surgeons’ rooms) and surgeons contributing to the ABDR were invited to review the BREAST-Q-IS. Participation was by individual semi-structured interviews by telephone or email, or by completion of a paper questionnaire. Transcripts of audio recordings and emailed text were analysed thematically. Results Twenty one breast implant recipients (10 after reconstruction and 11 augmentation), 8 surgeons (five plastic, three breast) and 2 medical professionals performing cosmetic surgeries were interviewed. Six themes were identified: Overall impression, Emotional response to the BREAST-Q IS, Method of follow-up, Suggested improvements, Group variation, and Potential Clinical utility. Overall, breast implant recipients and surgeons found the BREAST-Q IS to be acceptable and unlikely to provoke strong emotional reactions. Email was the preferred mode of contact. Most suggested improvements were to add questions. Surgeons expressed concern that subjective responses to the PROM might not accurately reflect experiences and that the PROM would predict need for revision rather than device failure. Conclusion This study supports the acceptability and feasibility of BREAST-Q IS as a PROM for recipients of breast implants. Further validation of the Breast-Q IS is required.

Details

Language :
English
ISSN :
25098020
Volume :
3
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Patient-Reported Outcomes
Publication Type :
Academic Journal
Accession number :
edsdoj.01c7f57025f944a092dd7d51a28f97e9
Document Type :
article
Full Text :
https://doi.org/10.1186/s41687-019-0152-z