Back to Search
Start Over
The Efficacy of the Dyson Air Purifier in Improving Asthma Control: Protocol for a Single-Center, Investigator-Led, Randomized, Double-Blind, Placebo-Controlled Trial
- Source :
- JMIR Research Protocols, Vol 10, Iss 7, p e28624 (2021)
- Publication Year :
- 2021
- Publisher :
- JMIR Publications, 2021.
-
Abstract
- BackgroundIndoor air quality has been shown to influence asthma control and outcomes. Air purifiers and high-efficiency particulate air filtration devices can improve indoor air quality by reducing the indoor levels of air pollution and allergens. However, the influence of this improved indoor air quality on asthma control remains unclear; hence, randomized controlled trials are needed to further elucidate this phenomenon. ObjectiveThis study aims to investigate the effect of reducing the levels of allergens and pollutants in the bedroom and living room through the use of Dyson air purifiers (Dyson Pure Cool) on asthma control. MethodsThis is an 18-month long, investigator-led, randomized, double-blinded, placebo-controlled, single-center trial. Subjects will be randomized in a 1:1 ratio to active or placebo Dyson filters. The primary outcome is the change in the scores of Asthma Control Questionnaire 6 and Asthma-specific Quality of Life Questionnaire from baseline. Secondary outcomes include changes in lung function (forced expiratory volume in one second, forced expiratory volume in one second/forced vital capacity ratio, and midexpiratory flows), peak expiratory flow measurements, airway hyperresponsiveness (assessed by methacholine bronchial challenge), fractional exhaled nitric oxide, and indoor air pollutant levels. The sample size will be 50 subjects, and all subjects will have a confirmed diagnosis of mild persistent to moderate persistent asthma along with an Asthma Control Questionnaire 6 score of >1.5. ResultsThis study was approved by the West Midlands Research Ethics Committee (18/WM/0277). The study results will be published in peer-reviewed scientific journals; presented at relevant scientific conferences; and shared in plain English with participants in our newsletters, in our clinics, and via the David Hide Asthma and Allergy Research Centre website. Our trial began in September 2019 and is expected to end in August 2021. ConclusionsThis is a double-blinded, placebo-controlled, randomized, investigator-led study to investigate the efficacy of a novel air purifier in improving asthma control in adults. The trial period of 18 months will facilitate the collection of robust data and will therefore generate clear signals. However, this extended trial duration may lead to patient withdrawal. Furthermore, this trial is conducted at a single center and in a location with a homogenous cohort of people, which may affect translatability. Nonetheless, it is hoped that the findings of this trial may help further inform clinicians regarding the utility of this novel device as an adjunct in asthma care. Trial RegistrationClinicalTrials.gov NCT04729530; https://clinicaltrials.gov/ct2/show/NCT04729530 International Registered Report Identifier (IRRID)DERR1-10.2196/28624
- Subjects :
- Medicine
Computer applications to medicine. Medical informatics
R858-859.7
Subjects
Details
- Language :
- English
- ISSN :
- 19290748
- Volume :
- 10
- Issue :
- 7
- Database :
- Directory of Open Access Journals
- Journal :
- JMIR Research Protocols
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.01ae9dfdd83b468e89577165d83f9c2c
- Document Type :
- article
- Full Text :
- https://doi.org/10.2196/28624