Back to Search Start Over

Novel Phase Detector Measurement Procedure Using Quasi-Synchronized RF Generator

Authors :
Pulido, V. A.
Cabrera-Almeida, F.
Quintana-Morales, P.
Mendieta-Otero, E.
Source :
IEEE Transactions on Instrumentation and Measurement, vol. 72, pp. 1-9, 2023
Publication Year :
2024

Abstract

This paper presents a new procedure for phase detector measurements that allows the use of generators that share a 10 MHz reference oscillator but do not synchronize in phase, in other words, quasi-synchronized RF generators. The objectives are taking advantage of the benefits of using two generators but recovering lower-cost generators that have worse synchronization performance and opening the door to the possibility of using a very simple control element based in Arduino Uno and cheaper instruments. The new procedure is characterized by continuously alternating calibration and measurement sequences to make up for the phase drift of quasisynchronized generators and guarantee a maximum phase error specification (+-1 grade in this paper). Data acquisition has been divided in two stages: measurement of detector curves without phase reference (in-phase and phase-shifted) and measurement of reference data. All the data is later combined to obtain correctly referenced in-phase detector curves. The technique can be reproduced with other equivalent instrumentation. The novel procedure that allows compensation for errors (amplitude, phase shift, mismatching, etc.) is detailed, and its relation to the required measurement accuracy is amply discussed. The proposed technique is applied to characterize a phase detector based on in-phase and phase-shifted multiplication from 3 to 8 GHz with 1 GHz step. Measurements have a final maximum error of +-2 grade for both frequency and calibrated input power, according to the accuracy specifications of the VNA used to calibrate the signal distribution network, added to the +-1 grade specified in this new procedure.<br />Comment: copyright 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works

Details

Database :
arXiv
Journal :
IEEE Transactions on Instrumentation and Measurement, vol. 72, pp. 1-9, 2023
Publication Type :
Report
Accession number :
edsarx.2402.04831
Document Type :
Working Paper
Full Text :
https://doi.org/10.1109/TIM.2023.3330210