Longevity Studies of CSC Prototypes Operating with Ar+CO$_{2}$ Gas Mixture and Different Fractions of CF$_{4}$

Authors :
Barberis, Emanuela
Begovic, Nebojsa
Haubrich, Nicholas
Ignatenko, Mikhail
Korytov, Andrey
Kukral, Ota
Kuznetsova, Ekaterina
Lanaro, Armando
MacCabe, Andrew
Milenovic, Predrag
Milovanovic, Dubravka
Mitselmakher, Guenakh
Radulovic, Aleksandra
Rajcic, Boris
Rosenzweig, Jake
Wang, Bingran
Wang, Jian
Wisecarver, Andrew
Wood, Darien
Yeager, Emma
Publication Year :
2024

Abstract

Studies of Cathode Strip Chamber longevity, comparing Ar+CO2 gas mixtures with fractions of 5%, 2%, and 0% CF4, were performed using several small cathode strip prototype chambers. In each trial, a localized source of radiation was used to irradiate up to an accumulated charge of about 300 mC/cm. Additionally, longevity of a uniformly irradiated prototype operating with 2% CF4 was studied at the CERN Gamma Irradiation Facility GIF++. Post-hoc analysis of the chamber electrodes using spectroscopy techniques was also done.

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2402.04181
Document Type :
Working Paper