Back to Search Start Over

Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source

Authors :
Aprile, E.
Abe, K.
Agostini, F.
Maouloud, S. Ahmed
Alfonsi, M.
Althueser, L.
Andrieu, B.
Angelino, E.
Angevaare, J. R.
Antochi, V. C.
Martin, D. Antón
Arneodo, F.
Baudis, L.
Baxter, A. L.
Bellagamba, L.
Biondi, R.
Bismark, A.
Brown, A.
Bruenner, S.
Bruno, G.
Budnik, R.
Bui, T. K.
Cai, C.
Capelli, C.
Cardoso, J. M. R.
Cichon, D.
Colijn, A. P.
Conrad, J.
Cuenca-García, J. J.
Cussonneau, J. P.
D'Andrea, V.
Decowski, M. P.
Di Gangi, P.
Di Pede, S.
Diglio, S.
Eitel, K.
Elykov, A.
Farrell, S.
Ferella, A. D.
Ferrari, C.
Fischer, H.
Fulgione, W.
Gaemers, P.
Gaior, R.
Rosso, A. Gallo
Galloway, M.
Gao, F.
Glade-Beucke, R.
Grandi, L.
Grigat, J.
Guida, M.
Hammann, R.
Higuera, A.
Hils, C.
Hoetzsch, L.
Howlett, J.
Iacovacci, M.
Itow, Y.
Jakob, J.
Joerg, F.
Joy, A.
Kato, N.
Kara, M.
Kavrigin, P.
Kazama, S.
Kobayashi, M.
Koltman, G.
Kopec, A.
Kuger, F.
Landsman, H.
Lang, R. F.
Levinson, L.
Li, I.
Li, S.
Liang, S.
Lindemann, S.
Lindner, M.
Liu, K.
Loizeau, J.
Lombardi, F.
Long, J.
Lopes, J. A. M.
Ma, Y.
Macolino, C.
Mahlstedt, J.
Mancuso, A.
Manenti, L.
Marignetti, F.
Undagoitia, T. Marrodán
Martens, K.
Masbou, J.
Masson, D.
Masson, E.
Mastroianni, S.
Messina, M.
Miuchi, K.
Mizukoshi, K.
Molinario, A.
Moriyama, S.
Morå, K.
Mosbacher, Y.
Murra, M.
Müller, J.
Ni, K.
Oberlack, U.
Paetsch, B.
Palacio, J.
Peres, R.
Peters, C.
Pienaar, J.
Pierre, M.
Pizzella, V.
Plante, G.
Qi, J.
Qin, J.
García, D. Ramírez
Reichard, S.
Rocchetti, A.
Rupp, N.
Sanchez, L.
Sanchez-Lucas, P.
Santos, J. M. F. dos
Sarnoff, I.
Sartorelli, G.
Schreiner, J.
Schulte, D.
Schulte, P.
Eißing, H. Schulze
Schumann, M.
Lavina, L. Scotto
Selvi, M.
Semeria, F.
Shagin, P.
Shi, S.
Shockley, E.
Silva, M.
Simgen, H.
Takeda, A.
Tan, P. -L.
Terliuk, A.
Thers, D.
Toschi, F.
Trinchero, G.
Tunnell, C.
Tönnies, F.
Valerius, K.
Volta, G.
Weinheimer, C.
Weiss, M.
Wenz, D.
Wittweg, C.
Wolf, T.
Xu, D.
Xu, Z.
Yamashita, M.
Yang, L.
Ye, J.
Yuan, L.
Zavattini, G.
Zerbo, S.
Zhong, M.
Zhu, T.
Geppert, C.
Riemer, J.
Publication Year :
2022

Abstract

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2211.14191
Document Type :
Working Paper
Full Text :
https://doi.org/10.1140/epjc/s10052-023-11512-z