Back to Search Start Over

High intensity proton beam impact at 440 GeV/c on Mo and Cu coated CfC/graphite and SiC/SiC absorbers for beam intercepting devices

Authors :
Maestre, Jorge
Bahamonde, Cristina
Garcia, Inigo Lamas
Kershaw, Keith
Biancacci, Nicolo
Busom, Josep
Frankl, Matthias
Lechner, Anton
Kurtulus, Adnan
Makimura, Shunsuke
Nakazato, Naofumi
Perez, Ana Teresa
Perillo-Marcone, Antonio
Salvant, Benoit
Seidenbinder, Regis
Teofili, Lorenzo
Calviani, Marco
Source :
Journal of Instrumentation (JINST) 2022 17 P01019
Publication Year :
2021

Abstract

Beam Intercepting Devices (BIDs) are essential protection elements for the operation of the Large Hadron Collider (LHC) complex. The LHC internal beam dump (LHC Target Dump Injection or LHC TDI) is the main protection BID of the LHC injection system; its main function is to protect LHC equipment in the event of a malfunction of the injection kicker magnets during beam transfer from the SPS to the LHC. Several issues with the TDI were encountered during LHC operation, most of them due to outgassing from its core components induced by electron cloud effects, which led to limitations of the injector intensity and hence had an impact on LHC availability. The absorbing cores of the TDIs, and of beam intercepting devices in general, need to deal with high thermo-mechanical loads induced by the high intensity particle beams. In addition, devices such as the TDI - where the absorbing materials are installed close to the beam, are important contributors to the accelerator impedance budget. To reduce impedance, the absorbing materials that make up the core must be typically coated with high electrical conductivity metals. Beam impact testing of the coated absorbers is a crucial element of development work to ensure their correct operation. The behaviour of several metal-coated absorber materials was investigated when exposed to high intensity and high energy proton beams in the HiRadMat facility at CERN. Different coating configurations based on copper and molybdenum, and absorbing materials such as isostatic graphite, Carbon Fibre Composite (CfC) and Silicon Carbide reinforced with Silicon Carbide fibres (SiC-SiC), were tested in the facility to assess the TDI's performance and to extract information for other BIDs using these materials. In addition to beam impact tests and an extensive Post Irradiation Examination (PIE) campaign, extensive numerical simulations were carried out.<br />Comment: 32 pages, 25 figures, accepted for publication in Journal of Instrumentation (JINST)

Details

Database :
arXiv
Journal :
Journal of Instrumentation (JINST) 2022 17 P01019
Publication Type :
Report
Accession number :
edsarx.2112.04792
Document Type :
Working Paper
Full Text :
https://doi.org/10.1088/1748-0221/17/01/P01019