Back to Search Start Over

Calcium imaging and analysis of the mouse hippocampus or neocortex using miniature microendoscopes

Authors :
Winne, Jessica
Nascimento, George
Nogueira, Ingrid
Leao, Richardson N.
Leao, Katarina E.
Publication Year :
2021

Abstract

Calcium imaging using miniscopes are becoming increasingly popular in the neuroscience community with a multitude of microendoscope versions, lens systems and packages for analysis available as open source. Here we describe in detail how to implant lenses and baseplates for the University of California at Los Angeles (UCLA) miniscope V3 and V4 using a Gradient Index (GRIN) lens for the hippocampus or a combination of prism and GRIN lens for recording in the neocortex. Our protocols contain adaptations from several published protocols however the GRIN-relay-Prism lens system protocol is developed in-house and not previously described. This chapter also suggests how lenses may be re-used and how to test the quality of a reused lens. Lastly, we comment on the difference between analysis software and the computational needs for different packages.<br />Comment: 22 pages, 5 figures, protocol, book chapter

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2110.00609
Document Type :
Working Paper