Back to Search Start Over

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

Authors :
Arnold, R.
Augier, C.
Barabash, A. S.
Basharina-Freshville, A.
Birdsall, E.
Blondel, S.
Bongrand, M.
Boursette, D.
Breier, R.
Brudanin, V.
Busto, J.
Calvez, S.
Cerna, C.
Cesar, J. P.
Ceschia, M.
Chapon, A.
Chauveau, E.
Chopra, A.
Dawson, L.
De Capua, S.
Duchesneau, D.
Durand, D.
Eurin, G.
Evans, J. J.
Filosofov, D.
Flack, R.
Franchini, P.
Girard-Carillo, C.
Gómez, H.
Guillon, B.
Guzowski, P.
Hoballah, M.
Hodák, R.
Hussain, M. H.
Jeremie, A.
Jullian, S.
Kaizer, J.
Klimenko, A.
Kochetov, O.
Konovalov, S. I.
Kovalenko, V.
Lalanne, D.
Lang, K.
Lemière, Y.
Noblet, T. Le
Liptak, Z.
Liu, X. R.
Loaiza, P.
Macko, M.
Macolino, C.
Marquet, C.
Mauger, F.
Minotti, A.
Mora, Y.
Morgan, B.
Mott, J.
Nemchenok, I.
Nomachi, M.
Nova, F.
Nowacki, F.
Ohsumi, H.
Oliviéro, G.
Pahlka, R. B.
Palušová, V.
Patrick, C.
Perrot, F.
Pin, A.
Piquemal, F.
Povinec, P.
Proga, M.
Quinn, W. S.
Ramachers, Y. A.
Remoto, A.
Reyss, J. L.
Saakyan, R.
Salamatin, A.
Salazar, R.
Sarazin, X.
Sedgbeer, J.
Shitov, Yu.
Simard, L.
Šimkovic, F.
Smolnikov, A.
Söldner-Rembold, S.
Štekl, I.
Suhonen, J.
Sutton, C. S.
Szklarz, G.
Tedjditi, H.
Thomas, J.
Timkin, V.
Torre, S.
Tretyak, Vl. I.
Tretyak, V. I.
Umatov, V. I.
Vilela, C.
Vorobel, V.
Waters, D.
Xie, F.
Žemlička, J.
Publication Year :
2021

Abstract

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0\nu\beta\beta$), and study the Standard-Model double-beta decay process ($2\nu\beta\beta$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($\beta\beta$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.<br />Comment: 16 pages, 12 figures, submitted to JINST, response to reviewer comments

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2103.14429
Document Type :
Working Paper
Full Text :
https://doi.org/10.1088/1748-0221/16/07/T07012