Back to Search Start Over

CMS RPC Background -- Studies and Measurements

Authors :
Hadjiiska, R.
Samalan, A.
Tytgat, M.
Zaganidis, N.
Alves, G. A.
Marujo, F.
De Araujo, F. Torres Da Silva
Da Costa, E. M.
Damiao, D. De Jesus
Nogima, H.
Santoro, A.
De Souza, S. Fonseca
Aleksandrov, A.
Iaydjiev, P.
Rodozov, M.
Shopova, M.
Sultanov, G.
Bonchev, M.
Dimitrov, A.
Litov, L.
Pavlov, B.
Petkov, P.
Petrov, A.
Qian, S. J.
Bernal, C.
Cabrera, A.
Fraga, J.
Sarkar, A.
Elsayed, S.
Assran, Y.
Sawy, M. El
Mahmoud, M. A.
Mohammed, Y.
Combaret, C.
Gouzevitch, M.
Grenier, G.
Laktineh, I.
Mirabito, L.
Shchablo, K.
Bagaturia, I.
Lomidze, D.
Lomidze, I.
Bhatnagar, V.
Gupta, R.
Kumari, P.
Singh, J.
Amoozegar, V.
Boghrati, B.
Ebraimi, M.
Ghasemi, R.
Najafabadi, M. Mohammadi
Zareian, E.
Abbrescia, M.
Aly, R.
Elmetenawee, W.
De Filippis, N.
Gelmi, A.
Iaselli, G.
Leszki, S.
Loddo, F.
Margjeka, I.
Pugliese, G.
Ramos, D.
Caponero, M.
Benussi, L.
Bianco, S.
Colafranceschi, S.
Russo, A.
Passamonti, L.
Piccolo, D.
Pierluigi, D.
Saviano, G.
Buontempo, S.
Di Crescenzo, A.
Fienga, F.
De Lellis, G.
Lista, L.
Meola, S.
Paolucci, P.
Braghieri, A.
Salvini, P.
Montagna, P.
Riccardi, C.
Vitulo, P.
Francois, B.
Kim, T. J.
Park, J.
Choi, S. Y.
Hong, B.
Lee, K. S.
Goh, J.
Lee, H.
Eysermans, J.
Estrada, C. Uribe
Pedraza, I.
Castilla-Valdez, H.
Sanchez-Hernandez, A.
Herrera, C. A. Mondragon
Navarro, D. A. Perez
Sanchez, G. A. Ayala
Carrillo, S.
Vazquez, E.
Radi, A.
Ahmad, A.
Asghar, I.
Hoorani, H.
Muhammad, S.
Shah, M. A.
Crotty, I.
Publication Year :
2020

Abstract

The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert \eta \rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.<br />Comment: 6 pages, Conference proceeding for the 2020 Resistive Plate Chambers and Related Detectors. Minor revision of the report, the results remain unchanged. Three new plots are added and some details were explained better

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2005.12769
Document Type :
Working Paper