Back to Search Start Over

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

Authors :
Gallina, G.
Giampa, P.
Retiere, F.
Kroeger, J.
Zhang, G.
Ward, M.
Margetak, P.
Lic, G.
Tsang, T.
Doria, L.
Kharusi, S. Al
Alfaris, M.
Anton, G.
Arnquist, I. J.
Badhrees, I.
Barbeau, P. S.
Beck, D.
Belov, V.
Bhatta, T.
Blatchford, J.
Brodsky, J. P.
Brown, E.
Brunner, T.
Cao, G. F.
Cao, L.
Cen, W. R.
Chambers, C.
Charlebois, S. A.
Chiu, M.
Cleveland, B.
Coon, M.
Craycraft, A.
Dalmasson, J.
Daniels, T.
Darroch, L.
Daugherty, S. J.
Croix, A. De St.
Der Mesrobian-Kabakian, A.
DeVoe, R.
Dilling, J.
Ding, Y. Y.
Dolinski, M. J.
Dragone, A.
Echevers, J.
Elbeltagi, M.
Fabris, L.
Fairbank, D.
Fairbank, W.
Farine, J.
Feyzbakhsh, S.
Fontaine, R.
Gautam, P.
Giacomini, G.
Gornea, R.
Gratta, G.
Hansen, E. V.
Heffner, M.
Hoppe, E. W.
Hoßl, J.
House, A.
Hughes, M.
Ito, Y.
Iverson, A.
Jamil, A.
Jewell, M. J.
Jiang, X. S.
Karelin, A.
Kaufman, L. J.
Kodroff, D.
Koffas, T.
Krucken, R.
Kuchenkov, A.
Kumar, K. S.
Lana, Y.
Larson, A.
Lenardo, B. G.
Leonarda, D. S.
Lik, S.
Li, Z.
Licciardi, C.
Linw, Y. H.
Lv, P.
MacLellan, R.
McElroy, T.
Medina-Peregrina, M.
Michel, T.
Mong, B.
Moore, D. C.
Murray, K.
Nakarmi, P.
Newby, R. J.
Ning, Z.
Njoya, O.
Nolet, F.
Nusair, O.
Odgers, K.
Odian, A.
Oriunno, M.
Orrell, J. L.
Ortega, G. S.
Ostrovskiy, I.
Overman, C. T.
Parent, S.
Piepkez, A.
Pocar, A.
Pratte, J. -F.
Qiu, D.
Radeka, V.
Raguzin, E.
Rescia, S.
Richman, M.
Robinson, A.
Rossignol, T.
Rowson, P. C.
Roy, N.
Saldanha, R.
Sangiorgio, S.
VIII, K. Skarpaas
Soma, A. K.
St-Hilaire, G.
Stekhanov, V.
Stiegler, T.
Sun, X. L.
Tarka, M.
Todd, J.
Tolba, T.
Totev, T. I.
Tsang, R.
Vachon, F.
Veeraraghavan, V.
Visser, G.
Vuilleumier, J. -L.
Wagenpfeil, M.
Walent, M.
Wang, Q.
Watkins, J.
Weber, M.
Wei, W.
Wen, L. J.
Wichoski, U.
Wu, S. X.
Wu, W. H.
Wu, X.
Xia, Q.
Yang, H.
Yang, L.
Yen, Y. -R.
Zeldovich, O.
Zhao, J.
Zhou, Y.
Ziegler, T.
Publication Year :
2019

Abstract

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.1903.03663
Document Type :
Working Paper
Full Text :