Back to Search Start Over

A compensated multi-gap RPC with 2 m-long strips for the LEPS2 experiment

Authors :
Watanabe, K.
Tanaka, S.
Chang, W. C.
Chen, H.
Chu, M. L.
Cuenca-Garcia, J. J.
Gogami, T.
Gonzalez-Diaz, D.
Niiyama, M.
Ohashi, Y.
Ohnishi, H.
Tomida, N.
Yosoi, M.
Publication Year :
2018

Abstract

We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in a mirrored configuration. A time resolution of sigma ~ 80 ps was achieved for any position within a strip (at above 99% detection efficiency); after performing the time-charge slewing correction, this value could be reduced to 60 ps. A link between the small contribution of the slewing correction to timing and the suppression of modal dispersion in the detector could be established.