Back to Search
Start Over
Methodology for the optimization of detection systems of Plasma corpuscular radiation, working under intensive conditions of n-g background radiation
- Source :
- Technical University of Saint Petersburg Library, 2000
- Publication Year :
- 2018
-
Abstract
- This Thesis present the process of development very low sensitivity to background radiation n-g scintillation detectors with close to 100% efficiency to corpuscular diagnostic of thermonuclear plasma. The detectors developed using this methodology were installed in two major Neutral Particle Analyzers for the JET tokamak (Gemma-2M and ISEP) and they operated successfully for many years. The configuration for such detectors is based on the growing of very thin scintillators of CsI(Tl) on top of quartz supporters and then glued to photomultipliers by keeping the thickness of the supporter and the entrance window of the photocamera of the photomultiplier very thin low sensitivity to background radiation can be achieved.<br />Comment: 104 pages, in Russian, 47 figures
- Subjects :
- Physics - Instrumentation and Detectors
F.2.2
I.2.7
Subjects
Details
- Language :
- Russian
- Database :
- arXiv
- Journal :
- Technical University of Saint Petersburg Library, 2000
- Publication Type :
- Report
- Accession number :
- edsarx.1801.01805
- Document Type :
- Working Paper