Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout
- Source :
- Nuclear Inst. Meth. A848 (2017), pp. 54-59
- Publication Year :
- 2016
-
Abstract
- Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.<br />Comment: 7 pages, 11 figures, version accepted for publication in NIM A