Back to Search Start Over

Measurement of time resolution of the Mu2e LYSO calorimeter prototype

Authors :
Atanov, N.
Baranov, V.
Colao, F.
Cordelli, M.
Corradi, G.
Dané, E.
Davydov, Yu. I.
Flood, K.
Giovannella, S.
Glagolev, V.
Happacher, F.
Hitlin, D. G.
Martini, M.
Miscetti, S.
Miyashita, T.
Morescalchi, L.
Pezzullo, G.
Saputi, A.
Sarra, I.
Soleti, S. R.
Tassielli, G.
Tereshchenko, V.
Source :
Nucl.Instrum.Meth. A812 (2016) 104-111
Publication Year :
2015

Abstract

In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the $e^-$ beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO crystals read out by 10x10 mm$^2$ Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as $\sigma_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b$, with the stochastic and constant terms $a=(51\pm1)$ ps and $b=(10\pm4)$ ps, respectively. This corresponds to the time resolution of ($162\pm4$) ps at 100 MeV.<br />Comment: 18 pages, 14 figures, accepted for the journal Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Details

Database :
arXiv
Journal :
Nucl.Instrum.Meth. A812 (2016) 104-111
Publication Type :
Report
Accession number :
edsarx.1509.04468
Document Type :
Working Paper
Full Text :
https://doi.org/10.1016/j.nima.2015.12.055