Back to Search Start Over

Extraction Method of Fine Granular Performance from Scintillator Strip Electromagnetic Calorimeter

Authors :
Kotera, Katsushige
Jeans, Daniel
Miyamoto, Akiya
Takeshita, Tohru
Source :
Nucl. Instrum. Meth. A789 (2015) 158-164
Publication Year :
2014

Abstract

We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle flow reconstruction to future experiments in high energy physics. Tests of this algorithm in full detector simulations, using strips of size 45 x 5 mm^2 show that the performance is close to that of a calorimeter with true 5 x 5 mm^2 readout granularity. The performance can be further improved by the use of 10 x 10 mm^2 tile- shaped layers interspersed between strip layers.<br />Comment: 11 pages, 10 figures