Back to Search Start Over

Beam test of the QMB6 calibration board and HBU0 prototype

Authors :
Cvach, Jaroslav
Kvasnicka, Jiri
Polak, Ivo
Zalesak, Jaroslav
Publication Year :
2011

Abstract

We report about the performance of the HBU0 board and the optical calibration system QMB6 in the DESY test beam. A MIP signal was measured on the HBU0 board, providing a reference to the LED amplitude scan, showing an amount of light delivered to each of 12 SiPMs from 0 to 250 MIP at maximum. An ASIC analogue memory cell performance was analyzed in relation with the SiPM signal strength. We observed a non-uniformity and a pedestal shift in the ASIC readout values in the high gain mode for the higher signals strength.<br />Comment: 12 pages, 16 figures, EUDET project memo

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.1105.4745
Document Type :
Working Paper