Back to Search Start Over

Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively

Authors :
Ribot, Emeline
Wecker, Didier
Trotier, Aurélien
Dallaudière, Benjamin
Lefrançois, William
Thiaudière, Eric
Franconi, Jean-Michel
Miraux, Sylvain
Centre de résonance magnétique des systèmes biologiques (CRMSB)
Centre National de la Recherche Scientifique (CNRS)-Université de Bordeaux (UB)
Bruker BioSpin MRI GmbH [Ettlingen, Germany]
CHU Bordeaux [Bordeaux]
Source :
PLoS ONE, PLoS ONE, Public Library of Science, 2015, 10 (10), pp.e0139249. ⟨10.1371/journal.pone.0139249⟩, PLoS ONE, Vol 10, Iss 10, p e0139249 (2015)
Publication Year :
2015
Publisher :
HAL CCSD, 2015.

Abstract

International audience; Introduction: The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field.Methods: In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On Resonance or shifted by a maximum of 3/4TR. Mice and human volunteers were imaged at 7T and 3T, respectively to perform whole-body and musculoskeletal imaging. “Sum-Of-Square” reconstruction was performed and combined or not with parallel imaging.Results: The frequency selectivity of 1-2-3-2-1 or 1-3-3-1 binomial pulses was preserved after (3/4TR) frequency shifting. Consequently, whole body small animal 3D imaging was performed at 7T and enabled visualization of small structures within adipose tissue like lymph nodes. In parallel, this method allowed 3D musculoskeletal imaging in humans with high spatial resolution at 3T. The combination with parallel imaging allowed the acquisition of knee images with ~500μm resolution images in less than 2min. In addition, ankles, full head coverage and legs of volunteers were imaged, demonstrating the possible application of the method also for large FOV.Conclusion: In conclusion, this robust method can be applied in small animals and humans at high magnetic fields. The high SNR and tissue contrast obtained in short acquisition times allows to prescribe bSSFP sequence for several preclinical and clinical applications.

Details

Language :
English
ISSN :
19326203
Database :
OpenAIRE
Journal :
PLoS ONE, PLoS ONE, Public Library of Science, 2015, 10 (10), pp.e0139249. ⟨10.1371/journal.pone.0139249⟩, PLoS ONE, Vol 10, Iss 10, p e0139249 (2015)
Accession number :
edsair.pmid.dedup....319a7b6734f93d978d1a4732541de3b4
Full Text :
https://doi.org/10.1371/journal.pone.0139249⟩