- TRAb Dade kit is a radioreceptor assay that detects autoantibodies in serum of patients with thyroid diseases which interfere with the binding of 125I labeled TSH to its receptor. In this paper we examined the basic and clinical usefulness of newly developed TRAb assay kits. The intra and inter assay coefficients of variation were 7.9% and 8.4%, respectively. There was no significant effect of temperature and incubation time on TRAb values. The influence of conjugated, unconjugated bilirubin, hemoglobin and turbidity was not so significant on TRAb values. TRAb values in serum of 68 untreated Graves' disease were above the normal range, but most (78%) treated Graves' patients who became euthyroid after receiving antithyroid drug, showed the normal range. In patients with chronic renal failure TRAb values were also within the normal range. A significant correlation (y = 1.0x-0.88, r = 0.95) was observed between this TRAb kit and TRAb Cosmic values in various thyroid conditions. This new assay for TRAb was simple, rapid and reproducible. The measurement of serum TRAb values was useful for the evaluation of physiological and pathological function and seemed to be helpful in the management of patients with thyroid disease.