Back to Search Start Over

Systematic evaluation of the highest current threshold for regional anaesthesia in a porcine model

Authors :
T, Steinfeldt
J, Graf
T, Vassiliou
W, Nimphius
K, Sturm
C, Kill
T, Wiesmann
H, Wulf
H-H, Müller
Source :
Acta anaesthesiologica Scandinavica. 54(6)
Publication Year :
2010

Abstract

The purpose of this study was to determine systematically the highest minimal stimulation current threshold for regional anaesthesia in pigs.In an established pig model for regional anaesthesia, needle placements applying electric nerve stimulation were performed. The primary outcome was the frequency of close needle to nerve placements as assessed by resin injects and subsequent anatomical evaluation. Following a statistical model (continual reassessment method), the applied output currents were selected to limit the necessary number of punctures, while providing guidance towards the highest output current range.Altogether 186 punctures were performed in 11 pigs. Within the range of 0.3-1.4 mA, no distant needle to nerve placement was found. In the range of 1.5-4.1 mA, 43 distant needle to nerve placements occurred. The range of 1.2-1.4 mA was the highest interval that resulted in a close needle to nerve placement rate ofor =95%.In the range of 0.3-1.4 mA, all resin deposition was found to be adjacent to nerve epineurium. The application of minimal current intensities up to 1.4 mA does not obviously lead to a reduction of epineural injectate contacts in pigs. These findings suggest that stimulation current thresholds up to 1.4 mA result in equivalent needle tip localisation in pigs.

Details

ISSN :
13996576
Volume :
54
Issue :
6
Database :
OpenAIRE
Journal :
Acta anaesthesiologica Scandinavica
Accession number :
edsair.pmid..........e451a6145742cb5e8748a5bf0d8f9010