Back to Search Start Over

[Inflammatory responses to wear particles in vivo: a novel model in the murine knee joint]

Authors :
S P, Zysk
H H, Gebhard
C, Pellengahr
H J, Refior
W, Plitz
K, Messmer
A, Veihelmann
Source :
Der Orthopade. 32(4)
Publication Year :
2003

Abstract

Although it is now widely recognized that the inflammatory response to implant wear particles plays an important role in aseptic loosening of total joint replacements, the precise mechanisms of this process remain unclear. The aim of this study was to establish an animal model for the study of the adverse response to particulate wear debris and the effects on the synovial microcirculation as well as the leukocyte-endothelial cell interaction in the murine knee joint in vivo. Balb/c mice were injected with 50 microl of a 0.5-microm polystyrene particle suspension (0.1% v/v) into the knee joint. The severity of the inflammatory response was evaluated at days 1, 2, 3, 5, 7 (acute), 21 (intermediate), and 63 (chronic) after particle injection. Histological examination as well as assessment of the synovial microcirculation using intravital microscopy was performed. For the intravital microscopy measurements, the patella tendon was partially resected for visualization of the synovial tissue of the knee joint and the fluorescent markers FITC-dextran and rhodamine 6G were injected intravenously. There was a significantly enhanced leukocyte-endothelial cell interaction beginning at day 3 after particle injection with a maximum in the acute phase (days 5-7) and a subsequent decline in the intermediate (day 21) and chronic (day 63) phases. Functional capillary density was significantly increased from day 3 until day 21 after particle application. The histological examination showed an inflammatory reaction that complied widely with the temporal course of the microvascular parameters and resembled the histological appearance of the synovial-like membrane around loose joint prostheses. A novel model was established for the qualitative and quantitative investigation of the particle-induced inflammatory response in the joint environment. It was shown for the first time that there is a significantly enhanced leukocyte-endothelial cell interaction in the synovial tissue after intra-articular particle injection. This model seems to be suitable for further investigations, e.g., dealing with the biocompatibility of different particle materials.

Details

Language :
German
ISSN :
00854530
Volume :
32
Issue :
4
Database :
OpenAIRE
Journal :
Der Orthopade
Accession number :
edsair.pmid..........cd07d2544677dfa8c40a5f9111c8e3b5