[A method for determination of volatile organic compounds in drinking water by purge and trap in combination with gas chromatograph/mass spectrometry]

Authors :
Ying-Hua, Xu
Bing-Hui, Zhu
Ye, Yang
Shao-Xia, Li
Source :
Wei sheng yan jiu = Journal of hygiene research. 35(5)
Publication Year :
2006

Abstract

To establish a method of purge and trap in combination with gas chromatograph/mass spectrometry(P and T-GC/MS) for the rapid determination of minimum multi-mixture of volatile organic compounds (VOCs) in drinking water simultaneously.The experimental conditions of P and T, such as desorption temperature, desorption time, the type of the trap and the analytical conditions of GC were optimized. 54 VOCs in drinking water were determined by P and T-GC/MS.The method enjoyed a wide linear range and good precision, the method detection limit(MDL) was 0.01 - 0.5 microg/L, the average recoveries of the method was 90% - 110% and the relative standard deviation (RSD) was 1.24%-7.79%.The results showed that the method was accurate and high sensitivity and might be good for application and suitable for trace analysis of VOCs in drinking water.