Comparison of anti-human and anti-porcine factor VIII inhibitor levels in 63 patients with severe haemophilia A. A French Multicentric Study
- Source :
- Vox sanguinis. 64(4)
- Publication Year :
- 1993
-
Abstract
- The levels of anti-human and anti-porcine factor VIII inhibitors, measured in 63 severe haemophilia A patients, lay in the ranges of0.2-2,600 and0.2-1,300 Bethesda units per ml (BU/ml), respectively, with a median cross-reactivity of 33%. In 4 patients, human and porcine inhibitor levels were determined using both plasma, either human or porcine, and factor VIII concentrate, either very high purity human or porcine (Hyate:C). A good correlation between titres was found, whatever the source of factor VIII (plasma or concentrate). The cross-reactivity varies from 0 to over 100%, indicating that the evaluation of both human and porcine inhibitors should be mandatory before any treatment with Hyate:C. Results show that of the 46 patients with human inhibitor of more than 5 BU/ml, 21 (46%) with a low porcine inhibitor (5 BU/ml) could benefit from Hyate:C.
Details
- ISSN :
- 00429007
- Volume :
- 64
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Vox sanguinis
- Accession number :
- edsair.pmid..........c54256c58e7efaceba51790adc4b9594